ASPYRE-Lung: Validation of a simple, fast, robust and novel method for multi-variant genomic analysis of actionable NSCLC variants in tissue

Avatar
Poster
Voice is AI-generated
Connected to paperThis paper is a preprint and has not been certified by peer review

ASPYRE-Lung: Validation of a simple, fast, robust and novel method for multi-variant genomic analysis of actionable NSCLC variants in tissue

Authors

Evans, R. T.; Gillon-Zhang, E.; Brown, J. N.; Knudsen, K. E.; King, C.; Green, A. S.; Silva, A.-L.; Mordaka, J. M.; Palmer, R. N.; Tomassini, A.; Collazos, A.; Xyrafaki, C.; Turner, I.; Ho, C. H.; Nugent, D.; Jose, J.; Andreazza, S.; von Bargen, K.; Gray, E. R.; Stolarek-Januszkiewicz, M.; Cooke, A.; Reddi, H.; Balmforth, B.; Osborne, R. J.

Abstract

Genomic variant testing of tumors is a critical gateway for patients to access the full potential of personalized oncology therapeutics. Current methods such as next-generation sequencing are costly and challenging to interpret, while PCR assays are limited in the number of variants they can cover. We developed ASPYRE (Allele-Specific PYrophosphorolysis REaction) technology to address the urgent need for rapid, accessible and affordable diagnostics informing actionable genomic target variants of a given cancer. The targeted ASPYRE-Lung panel for non-small cell carcinoma covers 114 variants in 11 genes (ALK, BRAF, EGFR, ERBB2, KRAS, RET, ROS1, MET & NTRK1/2/3) to robustly inform clinical management. The assay detects single nucleotide variants, insertions, deletions, and gene fusions from tissue-derived DNA and RNA simultaneously. We tested the limit of detection, specificity, analytical accuracy and analytical precision of ASPYRE-Lung using FFPE lung tissue samples from patients with non-small cell lung carcinoma, variant-negative FFPE tissue from healthy donors, and FFPE-based contrived samples with controllable variant allele fractions. The sensitivity of ASPYRE-Lung was determined to be [≤] 3% variant allele fraction for single nucleotide variants and insertions or deletions, 100 copies for fusions, and 200 copies for MET exon 14 skipping. The specificity was 100% with no false positive results. The analytical accuracy test yielded no discordant calls between ASPYRE-Lung and expected results for clinical samples (via orthogonal testing) or contrived samples, and results were replicable across operators, reagent lots, runs, and real-time PCR instruments with a high degree of precision. The technology is simple and fast, requiring only four reagent transfer steps using standard laboratory equipment (PCR and qPCR instruments) with analysis via a cloud-based analysis algorithm. The ASPYRE-Lung assay has the potential to be transformative in facilitating access to rapid, actionable molecular profiling of tissue for patients with non-small cell carcinoma.

Follow Us on

0 comments

Add comment